Home > Products >  attack hose psi dimensions
Email:[email protected]

Leave a Reply

attack hose psi dimensions

The Interior Attack Line: Getting the Most Bang for Your …

2006/1/10· I guess it all depends if that is all the type of hose your departent uses and how far the building or target is off the road. Using a fog nozzle, the engine pressure would be so high that it could damage the pumps. Well over 300 psi for the 750 ft layout. Normally, 5

Sizing the Initial Attack Hoseline | Firehouse

If you are presently using 1-1/2” line, take a look at 125 to 150-GPM coination nozzles that operate at 50 to 75-PSI nozzle pressures.

Large Diameter Hose (LDH) LAY FLAT Water Transfer

LDH Lay Flat Water Transfer Hose Polyurethane (PU) Eagle Water Transfer PU 200 PSI for 8” & 10” - Designed for irrigation, pumping of sledge and liquid fertilizers, supply or drag hose • PU lining, Ribbed cover or smooth cover • High-tenacity synthetic jacket

Hose Protection – RYCO Hydraulics

Hose Tag Hose Tag, RHWT 750/760 SPRING GUARD 750/760 SPRING GUARD 750/760, DIEHARD, Spring Guard, TJ24D RYCO Quality Accreditations Newsletter Sign up for the latest RYCO news, updates involving our products and services. Submit

Service Testing of Fire Hose

The hose directly in back of the test cap or the nozzle shall be secured to avoid possible whipping or other uncontrolled reactions in the event of a hose burst. With the hose at 45 psi ± 5 psi (3.1 bar ± 0.35 bar or 310 kPa ± 35 kPa), it shall be checked for

Parker - -10 Hose Size, 5/8" ID x 0.94" OD, 6,000 psi Work …

Find -10 Hose Size, 5/8" ID x 0.94" OD, 6,000 psi Work Pressure Hydraulic Hose at MSC Industrial Supply, serving the metalworking, safety, and MRO industries for over 75 years The day you order it is the day we ship it. Call 1-800-645-7270 or your local MSC

Service Testing of Fire Hose

The hose directly in back of the test cap or the nozzle shall be secured to avoid possible whipping or other uncontrolled reactions in the event of a hose burst. With the hose at 45 psi ± 5 psi (3.1 bar ± 0.35 bar or 310 kPa ± 35 kPa), it shall be checked for

Coat Ready - Product Specifiion “The Best Attack …

1 3/4” DP17-1000 500 psi 1500 psi 6.5 2 1/4” .38 lbs. 2” DP20-1000 500 psi 1500 psi 4.5 2 2/5” .44 lbs. 2 1/2” DP25-1000 500 psi 1500 psi 2 3” .52 lbs. Performance Chart Key Hose reserves the right to modify any specifiion without prior notice to meet or

Coordinating High-Volume Water Supply Operations - …

2017/1/6· PDP equals 180 psi, one five-inch 800-foot-long hoseline: 180 psi minus 20 psi (attack engine intake) results in 160-psi total friction loss. 160 psi divided by eight (length of the hose) equals the friction loss per 100 feet. The end result is that one five-inch line with

// HOSE - ALFAGOMMA

Dimension how a hange ithou rio otice. 38 HOSE Item Code Dash mm inch mm inch Mpa psi Mpa psi mm inch kg/m lb/C ft 1000295 -4 6 1/4 11,5 0,45 35 5000 140 20000 50 1,97 0,09 6 1000483 -5 8 5/16 13,4 0,53 30 4300 120 17200 55 2

// HOSE - ALFAGOMMA

Dimension how a hange ithou rio otice. 38 HOSE Item Code Dash mm inch mm inch Mpa psi Mpa psi mm inch kg/m lb/C ft 1000295 -4 6 1/4 11,5 0,45 35 5000 140 20000 50 1,97 0,09 6 1000483 -5 8 5/16 13,4 0,53 30 4300 120 17200 55 2

HYDRAULIC HOSE FITTINGS & ADAPTERS

Dash mm in mm in Mpa psi Mpa psi mm in kg/m lb/ft 1000310 01 2,0 5/64" 5,00 0,20 63,0 9100 190,0 27300 20,0 0,79 0,020 0,02 //eO Fl X r 7 SAE 100 R7 - EN 855 R7 Tube: polyester. Reinforcement: one/two high tensile textile braids. Cover: abrasion, ozone

Sizing the Initial Attack Hoseline | Firehouse

While much has been discussed and presented about proper size up and advancing the initial attack hose take a look at 125 to 150-GPM coination nozzles that operate at 50 to 75-PSI nozzle

Table of Contents - Parker Hannifin

The hose has a 5,800 psi rating. Therefore the maximum pressure rating of the hose assely would be 5,800 psi. Pressure ratings for each Parker end connection can be found on the Pressure Rating of Hose End Connections – PSI Chart in Section E. in an

Polyurethane Tubing Specifiions - ISM

255 psi 100 psi 1/4" 95A – 3/32” x 5/32” 210 psi 85 psi 3/8" 95A – 0.107” x 3/16” 220 psi 90 psi 3/8" 95A – 1/8” x 1/4” 265 psi 105 psi 1/2" 95A – 0.160” x 1/4” 175 psi 70 psi 1/2" 95A – 1/4” x 3/8” 170 psi 70 psi 7/8" 95A – 5/16” x 15/32”

Gates 46571159 1/2" 3250 psi Black Hydraulic Hose

Gates 46571159, Hydraulic Hose, High Pressure, 1/2" Hose Inside Diameter, 0.80" Hose Outside Diameter, 2-Braids Of High-Tensile Steel Wire Reinforcement Need less than a reel? Click here Appliion: High-pressure hydraulic oil lines. Exceeds ISO 18752

The Interior Attack Line: Getting the Most Bang for Your …

2014/8/29· 180 psi for 100-psi NP and 40-psi FL per 100 feet. Out of the six handline examples, only one had a pump discharge pressure of greater than 200 psi. Additionally the 17⁄8-inch hose was able to lower the FL by 20 psi per 100 feet. With that being said, it is clear

KEY

DOUBLE JACKET ATTACK HOSE THE BEST ATTACK HOSE, GUARANTEED Diameter Part No. Service Test Proof Test Coefficient of Flow Bowl Size Weight Uncoupled 13/4" DP17-1000 500 psi 1000 psi 6.59 21/4" 0.38 lbs/ft 2" DP20-1000 500 psi 1000 psi /

Attack Lines | Firehouse

C. Attack Line Hose Loads 1. Minuteman load - hose load includes a certain amount, generally 100 feet, of shoulder load as part of the overall load; nozzle is positioned in middle of load 2. Stack

Aeroquip 3,000 psi Teflon Hose and Hose Asselies

All dimensions in inches. NOTE: Use an abrasion sleeve with AE246 Teflon hose in any appliion where the braid is subject to possible abrasion. Eaton offers two sleeve styles: AE546 hose with integral polyester chafeguard and AE446 hose with integral silicone firesleeve.

Fire Hose Basics - Fire Department families Home Page

Attack Hose Hose designed to be used to coat fires beyond the incipient stage. Attack hose shall have a minimum design operating test pressure of 275 psi. Attack Hose-1” Booster Line Rubber Hose: Used for Rubbish, Brush, Washdowns Requires High

Hose Technology - Hansa-Flex

HANSA-FLEX – System Partner for Hydraulics Hose Replacement Service – 24h hour rapid response Our 280 service vans from the hydraulic emergency service are always just a call away. Whether on the construction site, during the harvest or in industrial

Two-Inch Hose: the Lightweight Preconnected Little Big …

2014/6/9· The most common hose pressure ratings for attack line hose include a 1,200-pound-per-square-inch (psi) burst pressure and a 400-psi annual test pressure. According to that National Fire Protection Association (NFPA), this means the hose can be used at up to 360 psi on the fireground.

HOSE AND FITTINGS

3 Simple– no clamps, bands, wires or bolts required Fitting design and special hose construction assure a tight, leak-proof connection with maximum operating pressures up to 350 psi. Wide variety of appliions– for a range of system requirements SOCKETLESS hose …

Attack Lines | Firehouse

A. Use and Appliion of Attack Lines. 1. Consist of hoselines of 1-1/2-inch, 1-3/4-inch, 2-inch, and 2-1/2-inch. 2. Generally pre-connected to the apparatus and equipped with a nozzle. 3. In

Municipal Fire Hose Guide

Supreme hose sizes up to 3” were designed specifically for use as heavy duty attack hose. It is manufactured to a service test pressure rating of 400 psi (2760 kPa) and